16 resultados para skinfold thickness

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: In chronic renal failure patients under hemodialysis (HD) treatment, the availability of simple, safe, and effective tools to assess body composition enables evaluation of body composition accurately, in spite of changes in body fluids that occur in dialysis therapy, thus contributing to planning and monitoring of nutritional treatment. We evaluated the performance of bioelectrical impedance analysis (BIA) and the skinfold thickness sum (SKF) to assess fat mass (FM) in chronic renal failure patients before (BHD) and after (AHD) HD, using air displacement plethysmography (ADP) as the standard method. Design: This single-center cross-sectional trial involved comparing the FM of 60 HD patients estimated BHD and AHD by BIA (multifrequential; 29 women, 31 men) and by SKF with those estimated by the reference method, ADP. Body fat-free mass (FFM) was also obtained by subtracting the total body fat from the individual total weight. Results: Mean estimated FM (kg [%]) observed by ADP BHD was 17.95 +/- 0.99 kg (30.11% +/- 1.30%), with a 95% confidence interval (CI) of 16.00 to 19.90 (27.56 to 32.66); mean estimated FM observed AHD was 17.92 +/- 1.11 kg (30.04% +/- 1.40%), with a 95% CI of 15.74 to 20.10 (27.28 to 32.79). Neither study period showed a difference in FM and FFM (for both kg and %) estimates by the SKF method when compared with ADP; however, the BIA underestimated the FM and overestimated the FFM (for both kg and %) when compared with ADP. Conclusion: The SKF, but not the BIA, method showed results similar to ADP and can be considered adequate for FM evaluation in HD patients. (C) 2012 by the National Kidney Foundation, Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objetivo O objetivo deste estudo foi analisar a associação entre o processo maturacional, a insatisfação corporal e o comportamento alimentar inadequado, de acordo com o sexo, em jovens atletas. Métodos Participaram da pesquisa 580 indivíduos, de ambos os sexos, pertencentes a diferentes modalidades esportivas. Foram avaliados a maturação sexual, a maturação somática, a insatisfação corporal e o comportamento alimentar inadequado, por meio dos Critérios de Tanner, banco de Lohman, Body Shape Questionnaire e Eating Attitudes Test, respectivamente. O percentual de gordura foi estimado pela medição das dobras cutâneas, e a aferição de peso e de estatura foi utilizada para calcular o índice de massa corporal. Realizaram-se modelo Univariado de Covariância, regressão logística binária e regressão linear múltipla para análise dos dados. Resultados Os resultados demonstraram diferenças estatisticamente significativas (p<0,05) na insatisfação corporal entre os estágios maturacionais. Além disso, os meninos pré-púberes e púberes apresentaram maior probabilidade de insatisfação corporal em relação aos atletas pós-púberes (p<0,05), e o modelo de regressão logística mostrou associação entre os estágios maturacionais e o comportamento alimentar inadequado apenas no sexo masculino (p<0,05). Nas meninas, o processo maturacional explicou em 9% e 7% a variância da insatisfação corporal (p<0,05) e comportamento alimentar inadequado (p<0,05), respectivamente.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUÇÃO: A partir da década de 1990 foram iniciados os primeiros tratamentos cirúrgicos da obesidade em adolescentes, seguindo a sequência cirurgia bariátrica, perda ponderal e dismorfismo corporal, criando demanda por cirurgias plásticas para readequação do contorno corporal. O objetivo deste estudo foi identificar fatores associados a cirurgias plásticas de readequação de contorno corporal (morbidade e mortalidade), realizadas em pacientes submetidos a cirurgia bariátrica durante a adolescência. MÉTODO: Entre janeiro de 2008 e janeiro de 2011, 5 pacientes submetidos a gastroplastia redutora durante a adolescência, com consequente perda e estabilização de peso, foram submetidos a cirurgias plásticas do contorno corporal. A média de idade no início das cirurgias plásticas foi de 19,7 anos, sendo 3 (60%) pacientes do sexo feminino. Foram realizadas dermolipectomias abdominais em todos (100%) os pacientes, dermolipectomias crurais em 4 (80%), dermolipectomias braquiais em 2 (40%), mamoplastia com inclusão de implantes de silicone em 2 (40%) pacientes do sexo feminino, mastopexia na terceira paciente do sexo feminino (20%) e correção de ginecomastia em 1 (20%), toracoplastia em 2 (40%), torsoplastia em 2 (40%) e torsoplastia reversa em 1 (20%). Foram realizadas, em média, 3 intervenções cirúrgicas por paciente, sendo operados 20 sítios cirúrgicos. RESULTADOS: Ocorreram deiscências em 3 (15% dos sítios cirúrgicos) casos e foi necessário revisar a ressecção dermogordurosa por flacidez residual em 3 (15% dos sítios cirúrgicos) casos. CONCLUSÕES: Foram identificados alguns fatores associados às cirurgias plásticas de readequação de contorno corporal na amostra de 5 pacientes submetidos a cirurgia bariátrica durante a adolescência, comparáveis aos da literatura específica.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The double burden of obesity and underweight is increasing in developing countries and simple methods for the assessment of fat mass in children are needed. Aim: To develop and validate a new anthropometric predication equation for assessment of fat mass in children. Subjects and methods: Body composition was assessed in 145 children aged 9.8 +/- 1.3 (SD) years from Sao Paulo, Brazil using dual energy X-ray absorptiometry (DEXA) and skinfold measurements. The study sample was divided into development and validation sub-sets to develop a new prediction equation for FM (PE). Results: Using multiple linear regression analyses, the best equation for predicting FM (R-2 - 0.77) included body weight, triceps skinfold, height, gender and age as independent variables. When cross-validated, the new PE was valid in this sample (R-2 = 0.80), while previously published equations were not. Conclusion: The PE was more valid for Brazilian children that existing equations, but further studies are needed to assess the validity of this PE in other populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case report describes the presence of bilateral macular atrophy in a patient with Alport syndrome and compares this finding with literature. At fundoscopy, there was a discrete circumscribed macular thinning showing intense retinal pigment epithelium color and the presence of whitish circular retinal lesions ("dots" and "flecks") at nasal mid periphery of both eyes. Optical coherence tomography showed bilateral partial atrophy of the neurosensory retina in the macula, with a greater extent in the temporal region. This case describes a rare ophthalmological finding in Alport syndrome and important to be recognized for a precise diagnosis as well as for determining visual prognosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: An experimental in vitro study was carried out to evaluate the influence of cortical bone thickness on ultrasound propagation velocity. Methods: Sixty bone plates were used, made from bovine femurs, with thickness ranging from 1 to 6 mm (10 of each). The ultrasound velocity measurements were performed using a device specially designed for this purpose, in an underwater acoustic tank and with direct contact using contact gel. The transducers were positioned in two ways: on opposite sides, with the bone between them, for the transverse measurement; and parallel to each other, on the same side of the bone plates, for the axial measurements. Results: In the axial transmission mode, the ultrasound velocity speed increased with cortical bone thickness, regardless of the distance between the transducers, up to a thickness of 5 mm, then remained constant thereafter. There were no changes in velocity when the transverse measures were made. Conclusion: Ultrasound velocity increased with cortical bone thickness in the axial transmission mode, until the thickness surpasses the wavelength, after which point it remained constant. Level of Evidence: Experimental Study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To study changes in lamina cribrosa position and prelaminar tissue thickness (PTT) after surgical IOP reduction in glaucoma patients. METHODS. Twenty-two patients (mean age, 71.4 years) were imaged with spectral domain optical coherence tomography (SD-OCT; 24 radial B-scans centered on the optic nerve head [ONH]) before trabeculectomy or tube shunt implantation. Follow up images were acquired 1 week, 1 month, 3 months, and 6 months postsurgery. Bruch's membrane opening (BMO), the internal limiting membrane (ILM) and the anterior laminar surface (ALS) were segmented in each radial scan with custom software. Surfaces were fitted to the ILM and ALS with the extracted three-dimesional coordinates. PTT was the distance between the ILM and ALS, perpendicular to a BMO reference plane. Serial postsurgical laminar displacement (LD), relative to the BMO reference plane, and changes in PTT were measured. Positive values indicated anterior LD. RESULTS. Mean (SD) presurgery IOP was 18.1 (6.5) mm Hg, and reduced by 4.7 (5.5), 2.4 (7.7), 7.0 (6.2), and 6.8 (7.5) mm Hg at 1 week, 1 month, 3 months, and 6 months postsurgery, respectively. At the four postsurgery time points, there was significant anterior LD (1.8 [9.5], -1.1 [8.9], 8.8 [20.2], and 17.9 [25.8] mu m) and PTT increase (1.7 [13.3], 2.4 [11.9], 17.4 [13.7], and 13.9 [18.6] mu m). LD was greater in ONHs with larger BMO area (P = 0.01) and deeper ALS (P = 0.04); however, PTT was not associated with any of the tested independent variables. CONCLUSIONS. Both anterior LD and thickening of prelaminar tissue occur after surgical IOP reduction in patients with glaucoma. (Invest Ophthalmol Vis Sci. 2012;53:5819-5826) DOI:10.1167/iovs.12-9924

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to evaluate the thickness of the femoral quadriceps and biceps brachii and brachialis muscles bilaterally and the adjacent subcutaneous fat in patients undergoing gastric bypass Roux-en-Y before and after surgery, using ultrasound as the diagnostic method of choice. We studied 12 patients undergoing this surgical method preoperatively and during the first, third, and sixth postoperative months. During these periods, patients were evaluated by ultrasound to determine the thickness of subcutaneous adipose tissue and muscle of the upper and lower limbs. Postoperatively, these patients showed a reduction in the thickness of the upper and lower extremities muscle and adipose tissue as compared to their preoperative values. There was a significant difference in the loss of muscle thickness in all postoperative months and in the thickness of fatty tissue in the sixth month after surgery, compared to the preoperative muscle and fatty tissue thickness. Ultrasound can be considered as the diagnostic method of choice when assessment of the fat and lean body mass is required in morbidly obese patients before and after bariatric surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is well known that crystals of topaz from the Eastern Brazilian Pegmatite Province may turn blue by the irradiation with Co-60 gamma rays followed by heat treatment. Also, it is known that the sensation of color changes with the thickness of these crystals. The dependence of the color, given by 1931 CIE chromaticity coordinates, with the thickness of the crystal was analyzed. The absorbance used in the calculation of these coordinates was given by the sum of Gaussian lines. The parameters of these lines were determined through the decomposition of the optical absorption spectra in the ultraviolet and visible regions. The decomposition revealed several lines, whose assignment was made considering studies in spodumene and beryl crystals and highly accurate quantum mechanical calculations. The transmittance becomes very narrow with increasing thickness, and the CIE chromaticity coordinates converge to the borderline of the CIE Chromaticity Diagram at the wavelength of maximum transmittance. Furthermore, the purity of color increases with increasing thickness, and the dominant wavelength reaches the wavelength of maximum transmittance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work studies the gate-induced drain leakage (GIDL) in p- and n-MuGFET structures with different TiN metal gate thickness and high-k gate dielectrics. As a result of this analysis, it was observed that a thinner TiN metal gate showed a larger GIDL due to the different gate oxide thickness and a reduced metal gate work function. In addition, replacing SiON by a high-k dielectric (HfSiON) results for nMuGFETs in a decrease of the GIDL On the other hand, the impact of the gate dielectric on the GIDL for p-channel MuGFETs is marginal. The effect of the channel width was also studied, whereby narrow fin devices exhibit a reduced GIDL current in spite of the larger vertical electric field expected for these devices. Finally, comparing the effect of the channel type, an enhanced GIDL current for pMuGFET devices was observed. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The need to develop new dental luting agents in order to improve the success of treatments has greatly motivated research. Objective: The aim of this study was to evaluate the diametral tensile strength (DTS) and film thickness (FT) of an experimental dental luting agent derived from castor oil (COP) with or without addition of different quantities of filler (calcium carbonate - CaCO3). Material and Methods: Eighty specimens were manufactured (DTS N=40; FT N=40) and divided into 4 groups: Pure COP; COP 10%; COP 50% and zinc phosphate (control). The cements were mixed according to the manufacturers' recommendations and submitted to the tests. The DTS test was performed in the MTS 810 testing machine (10 KN, 0.5 mm/min). For FT test, the cements were sandwiched between two glass plates (2 cm(2)) and a load of 15 kg was applied vertically on the top of the specimen for 10 min. The data were analyzed by means of one-way ANOVA and Tukey's test (alpha=0.05). Results: The values of DTS (MPa) were: Pure COP- 10.94 +/- 1.30; COP 10%- 30.06 +/- 0.64; COP 50%- 29.87 +/- 0.27; zinc phosphate- 4.88 +/- 0.96. The values of FT (pm) were: Pure COP- 31.09 +/- 3.16; COP 10%- 17.05 +/- 4.83; COP 50%- 13.03 +/- 4.83; Zinc Phosphate- 20.00 +/- 0.12. One-way ANOVA showed statistically significant differences among the groups (DTS - p=1.01E-40; FT - p=2.4E-10). Conclusion: The experimental dental luting agent with 50% of filler showed the best diametral tensile strength and film thickness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previous study on the characterization of effective material properties of a d(15) thickness-shear piezoelectric Macro-Fibre Composite (MFC) made of seven layers (Kapton, Acrylic, Electrode, Piezoceramic Fibre and Epoxy Composite, Electrode, Acrylic, Kapton) using a finite element homogenization method has shown that the packaging reduces significantly the shear stiffness of the piezoceramic material and, thus, leads to significantly smaller effective electromechanical coupling coefficient k(15) and piezoelectric stress constant e(15) when compared to the piezoceramic fibre properties. Therefore, the main objective of this work is to perform a parametric analysis in which the effect of the variations of fibre volume fraction, Epoxy elastic modulus, electrode thickness and active layer thickness on the MFC effective material properties is evaluated. Results indicate that an effective d(15) MFC should use relatively thick fibres having relatively high shear modulus and relatively stiff epoxy filler. On the other hand, the electrode thickness does not affect significantly the MFC performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background Heart chambers rupture in blunt trauma is uncommon and is associated with a high mortality. The determinant factors, and the incidence of isolated heart chambers rupture remains undetermined. Isolated rupture of the right atrium appendage (RAA) is very rare, with 8 cases reported in the reviewed literature. The thin wall of the RAA has been presumed to render this chamber more prone to rupture in blunt trauma. Objective To report a case of isolated RAA rupture in blunt trauma, and to compare right atrium (RA) and RAA wall thickness in a necropsy study. Methods The thickness of RA and RAA wall of hearts from cadavers of fatal penetrating head trauma victims was measured. Our case of isolated RAA rupture is presented. The main findings of the 8 cases reported in the literature, and the findings of our case, were organized in a table. Result The comparison of the data showed that wall thickness of the RAA (0.53 ± 0.33 mm) was significantly thinner than that of RA (1.11 ± 0.42 mm) (p < 0.05). Comments In all these 9 cases of isolated RAA rupture, cardiac tamponade occurred, RAA rupture was diagnosed intraoperatively and sutured, and the patients survived. Main mechanisms hypothesized for heart chamber rupture include mechanical compression coincident with phases of cardiac cycle, leading to high hydrostatic pressure inside the chamber. Published series include numerous cases of RA rupture, and only a few cases of RAA rupture. Conclusion Thus, our data suggests that wall thickness is not a determinant factor for RA or RAA rupture in blunt trauma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated whether periodontal ligament (PL) thickness varied with root size and examined the possible influence of this variation on orthodontic mechanics. Measurements were taken of the maxillary left first molar in 54 male Wistar rats. Mean mesial and distal PL thicknesses were compared between the intermediate buccal and mesiobuccal roots using paired Student's t-tests with a 5% significance level. Mean values differed significantly between roots (p < 2.2 × 10-16). PL thickness in rats is directly proportional to root dimensions

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previous study on the characterization of effective material properties of a d15 thickness-shear piezoelectric Macro-Fibre Composite (MFC) made of seven layers (Kapton, Acrylic, Electrode, Piezoceramic Fibre and Epoxy Composite, Electrode, Acrylic, Kapton) using a finite element homogenization method has shown that the packaging reduces significantly the shear stiffness of the piezoceramic material and, thus, leads to significantly smaller effective electromechanical coupling coefficient k15 and piezoelectric stress constant e15 when compared to the piezoceramic fibre properties. Therefore, the main objective of this work is to perform a parametric analysis in which the effect of the variations of fibre volume fraction, Epoxy elastic modulus, electrode thickness and active layer thickness on the MFC effective material properties is evaluated. Results indicate that an effective d15 MFC should use relatively thick fibres having relatively high shear modulus and relatively stiff epoxy filler. On the other hand, the electrode thickness does not affect significantly the MFC performance.